Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Validez y confiabilidad del instrumento SEMSA “Medición de la autoeficacia percibida en apnea del sueño” (Perceived self-efficacy measure for sleep apnea). Versión en español

Mateus Galeano, Erika Marcela (2014) Validez y confiabilidad del instrumento SEMSA “Medición de la autoeficacia percibida en apnea del sueño” (Perceived self-efficacy measure for sleep apnea). Versión en español. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

5MB

Resumen

Al carecer de instrumentos en idioma español para medir la autoeficacia percibida en personas con apnea del sueño, la presente investigación tuvo como objetivo determinar la validez facial, de contenido, de constructo y la consistencia interna del instrumento SEMSA (Perceived Self-Efficacy Measure for Sleep Apnea) de Weaver y colaboradores. Se sustentó a partir de la Teoría de Autoeficacia de Albert Bandura, evaluando tres aspectos de la teoría mediante 27 ítems en escala tipo Likert. Los aspectos centrales de la teoría fueron la percepción del riesgo, las expectativas de resultados y la autoeficacia percibida en personas con apnea obstructiva del sueño ante el tratamiento con presión positiva continua en la vía aérea (CPAP). Se usó un diseño de tipo metodológico, con el fin de evaluar las propiedades psicométricas del instrumento de medición. Para la validez facial se aplicó un instrumento a 6 expertos quienes evaluaron las categorías de comprensión, claridad y precisión de los ítems del instrumento. En la validez de contenido 4 expertos determinaron mediante un Índice de Validez de Contenido modificado si el ítem era esencial, útil pero no esencial o no necesario. Para la validez de constructo y consistencia interna 151 pacientes con Síndrome de Apnea hipopnea del sueño que estuvieran en tratamiento con CPAP diligenciaron el instrumento. Este tamaño muestral resultó de un cálculo de error y precisión tipo II a partir de la desviación estándar de la muestra de la prueba piloto de 81 personas que cumplían con los mismos criterios de inclusión y exclusión determinadas para el estudio. Para la validez facial se obtuvo un índice de aceptabilidad > 0.80%, en la precisión, un índice de aceptabilidad de 0.77% en claridad y de un 1% los cuales se reconocen como acuerdo de aceptabilidad superior, entendiéndose que valores cercanos a 1 indican un mayor acuerdo entre evaluadores. Para la validez de contenido se encontró que en cuanto a la utilidad de cada ítem del instrumento SEMSA, de la escala total (27 ítems), 23 ítems alcanzaron un nivel de aceptabilidad satisfactorio. Los 4 ítems restantes aunque no se eliminaron fueron susceptibles de modificación. En la validez de constructo se realizó un análisis factorial exploratorio donde se obtuvieron tres cargas factoriales y una varianza total explicada de 52.2%. El Alfa de Cronbach obtenido fue de 0.90 para la escala total y dimensional por encima de 0.86. De acuerdo a lo anterior, se concluye que la versión en español del Instrumento SEMSA Medición de la Autoeficacia Percibida para la apnea del sueño, es válida y homogénea para la medición de la autoeficacia en pacientes con Síndrome de Apnea hipopnea del sueño exponiendo las recomendaciones para el uso de este instrumento en estudios futuros. Los resultados muestran que el instrumento es válido, en el contexto colombiano, en especifico para el área andina, población urbana, en la ciudad de Bogotá. A partir de lo cual se recomienda su utilización para el estudio de la autoeficacia percibida del paciente con SAHS en tratamiento con CPAP., Abstract. Lacking of instruments in Spanish language for measuring self-efficacy in people with sleep apnea, the present investigation had to as objective determine the facial validity of content, construct and the internal consistency of the instrument SEMSA (Perceived Self-Efficacy Measure for Sleep apnea) Weaver et al. Was based from the theory of Albert Bandura Self-Efficacy, evaluating three aspects of the theory by 27 items on Likert-type scale. The central aspects of the theory were risk perception, outcome expectations and self-efficacy in people with obstructive sleep apnea treatment with continuous positive pressure airway (CPAP). Methodological design was used, in order to assess the psychometric properties of the measuring instrument. For the facial validity was applied a instrument to 6 experts who evaluated the categories of understanding, clarity and precision of the instrument items. In the content validity 4 experts determined with a Content Validity Index modified if the item was essential, useful but not essential, or not necessary. For construct validity and internal consistency 151 patients with hypopnea syndrome Sleep apnea who were treated with CPAP completed the instrument. This sample size was of the calculation of error and accuracy type II from the standard deviation of the sample pilot of 81 people who met the same inclusion criteria and exclusion selected for study. To facial validity was obtained an acceptability index> 0.80% on accuracy, an acceptability index of 0.77% in clarity and 1% which are recognized as superior acceptability agreement, where values close to 1 indicate a greater agreement between reviewers. For content validity was found that the usefulness of each item of SEMSA instrument of full scale (27 items), 23 items reached a satisfactory level of acceptability. The remaining 4 items were not removed but were subject to change. In the construct validity was made of an exploratory factor analysis where got three factor loadings and total variance explained of 52.2%. The Cronbach's alpha obtained was of 0.90 for the total scale and dimensional above 0.86. According to the above, we conclude that the Spanish version of the instrument SEMSA Measuring Perceived Self-efficacy for sleep apnea, is valid and homogeneou for measuring self-efficacy in patients with hypopnea syndrome Sleep Apnea exposing recommendations for the use of this instrument in future studies. The results show that the instrument is valid, in the Colombian context, specific for the Andean area, urban population in the city of Bogotá, from which its use for the study of self-efficacy of patients with OSA treated with CPAP is recommended

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Céspedes Cuevas, Viviana Marycel
Información adicional:Magister en Enfermería. Línea de Investigación: Cuidado de enfermería para la salud cardiovascular
Palabras clave:Síndrome de apnea del sueño, Autoeficacia, Validez, Confiabilidad, Cuestionarios, Sleep apnea syndrome, Self efficacy, Validity of tests, Reproducibility of results, Questionnaires
Temática:6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Enfermería
Código ID:40205
Enviado por : Universidad Nacional de Colombia Biblioteca Digital - Sede Bogotá
Enviado el día :28 Agosto 2014 15:02
Ultima modificación:28 Agosto 2014 15:02
Ultima modificación:28 Agosto 2014 15:02
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox