Comportamiento del efecto corona en configuración coaxial bajo condiciones de presión controladas para el aire

Alarcón Villamil, Jorge Alexander (2012) Comportamiento del efecto corona en configuración coaxial bajo condiciones de presión controladas para el aire. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB
[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

93kB

Resumen

Este proyecto analiza el comportamiento del efecto corona en configuración coaxial, para condiciones de presión controlada entre 74 kPa y 550 Kpa de presión. Se estudia el comportamiento de la característica V‐I obtenida al aplicar señales de voltaje DC en el arreglo coaxial y la carga espacial cuando se aplican señales de impulso de tensión tipo rayo. Las pruebas se realizaron usando un arreglo de cinco tubos coaxiales conectados en paralelo, cada uno con un alambre concéntrico de 0.3 mm de diámetro. Las mediciones permitieron obtener la característica I‐V del arreglo coaxial y un modelo de regresión matemático que permite predecir el comportamiento de la corriente en función de la presión de trabajo y del voltaje aplicado al arreglo, garantizando un error promedio menor al 5 %. También se estudio la impedancia del arreglo coaxial, encontrando que presenta un comportamiento no lineal en función de la tensión, alcanzando valores elevados (G) en el instante que se supera el voltaje de inicio del efecto corona, que disminuyen conforme aumenta la tensión de prueba. El mismo comportamiento se observó con todas las presiones de trabajo usadas en el estudio. Las pruebas de impulso de tensión mostraron que se genera carga espacial cuando el voltaje aplicada sobrepasa el voltaje de inicio del efecto corona. Cuando esto sucede, se produce un impulso de corriente de electrones que viaja a través del aire en el arreglo coaxial generando una densidad de iones alrededor del alambre coaxial, que se conoce como carga espacial. El proceso de ionización descrito se puede presentar en una o dos etapas de ionización asociada a uno o dos pulsos de corriente producidos de forma consecutiva. El proceso de ionización de una etapa se presentó cuando la presión de trabajo era menor a 344.4 kPa, y el proceso de ionización en dos etapas se presentó cuando la presión era superior., Abstract. This research show the V‐I characteristics of the corona effect in a coaxial setup for a DC voltage signal and the spatial charge produced when lightning impulse voltage are applied, under controlled pressure conditions between 100 kpa and 560 kPa. The tests were made using an array of five coaxial tubes connected in parallel, each one with a 0.3 mm diameter concentric wire. Measurements and results was used for develop for tha I‐V characteristics and a fitting mathematical model which is capable to predict the corona current in the coaxial arrangement, for any pressure and any voltage selected within the range of the used values. The impedance of the coaxial setup was analyzed too, finding a higher impedance value near the corona inception voltage that decreases rapidly when the applied voltage exceeds onset corona voltage; this behaviour was observed for all pressure conditions. The results obtained for the lightning impulse shown that space charge is produced when the applied voltage is higher than the corona onset voltage. When the onset voltage is overtaken, one electron current pulse travel through the air gap and produce an ion volumetric charge density around the concentric wire, this one is named spatial charge. The ionization process occurs in one or two ionization steps. The one step ionization process was observed when the test pressure was low and the two steps ionization process occurred when pressure is high. Additionally, the spatial charge is higher when the test pressure is lower but decrease when pressure increase.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Román Campos, Francisco
Información adicional:Maestría en Ingeniería Eléctrica.
Palabras clave:Efecto corona vs presión, Característica I‐V del efecto corona, Carga espacial, Impulso tipo rayo, Modelo matemático para la corriente corona, Corona effect vs pressure, I‐V characteristics for corona effect, Spatial charge, Lightning voltage impulse, Corona current mathematical model
Temática:5 Ciencias naturales y matemáticas / Science > 51 Matemáticas / Mathematics
5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology
6 Tecnología (ciencias aplicadas) / Technology > 62 Ingeniería y operaciones afines / Engineering
Unidad administrativa:Sede Bogotá > Facultad de Ingeniería > Departamento de Ingeniería Eléctrica y Electrónica
Código ID:45409
Enviado por : Universidad Nacional de Colombia Biblioteca Digital -3- Sede Bogotá
Enviado el día :18 Noviembre 2014 22:02
Ultima modificación:18 Noviembre 2014 22:05
Ultima modificación:18 Noviembre 2014 22:05
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox