Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Diseño de cámara estática cerrada y medición de flujos de gases de efecto invernadero (GEI) en suelos

Arenas Calle, Laura Natalia (2016) Diseño de cámara estática cerrada y medición de flujos de gases de efecto invernadero (GEI) en suelos. Maestría thesis, Universidad Nacional de Colombia Sede Palmira.

Texto completo

[img]
Vista previa
PDF - Versión Enviada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB

Resumen

El suelo libera hacia la atmósfera una cantidad significativa de gases de efecto invernadero (GEI) como CH4, N2O y CO2 provenientes de diferentes usos del suelo. En el suelo, la técnica de la cámara estática cerrada es la técnica más usada para hacer mediciones de GEI y los científicos trabajan en mejorar la técnica y hacer más confiables los datos obtenidos. En el presente estudio, se evaluó el momento del día óptimo para medir GEI, fueron comparadas las mediciones hechas con diferentes diseños de cámara estática cerrada y metodologías de muestreo (Convencional y Gas Pooling), así como los intervalos de tiempo óptimos. Todas estas evaluaciones fueron llevadas a cabo en el Centro Internacional de Agricultura Tropical (CIAT) y las muestras fueron analizadas en el laboratorio de GEI usando cromatografía gaseosa. Los resultados mostraron que el tiempo del día óptimo fue entre las 8-12 pm, esto estuvo en de acuerdo con diferentes autores, sin embargo se considera que evitar los picos altos de temperatura en el día puede ser un buen criterio. Respecto a los diseños de cámaras, se encontraron diferencias significativas (P<0.05) entre los flujos de GEI de diferentes diseños. Estas diferencias pudieron deberse a las diferentes alturas de las cámaras, a la mezcla de la muestra o el alta diferencia de la temperatura del aire dentro del espacio de la cámara. Los flujos de N2O y el CH4, fueron más altos en el diseño convencional que en el diseño propuesto porque estos son gases traza y la cámara grande pudo perder sensibilidad (límite de detección). La metodología convencional y Gas Pooling, conservaron la misma tendencia en los flujos y difieren entre 1-6% en CH4, 10-20% en CO2, y 36% en N2O, en la mayoría de los casos este porcentaje se debe a puntos atípicos en el promedio, \\Abstract: The soil release to atmosphere a significant amount to GHG like CO2, CH4 and N2O from different land use. In the soil, the static chambers technique is the most used technique for measuring GHG, scientifics work in improve the technique and make more reliable the data obtained. In the present study, were evaluated the optimal time of daytime for GHG measuring, were compared of measurements made with different static closed chamber designs and methodology of sampling (Conventional and Gas Pooling) as well as the optimal time intervals for measuring GHG in soils. All evaluations were carried in the International Center of Tropical Agriculture (CIAT) and the samples were analized in GHG laboratory using gas cromathography. The results showed that the optimal time of daytime was between 8-12 pm, this was agreeing with different authors however, it is considered that avoid the high temperature peaks in the day, can be a good criteria. Respect to chamber designs, were found significative differences (P< 0.05) between GHG fluxes of diffentes designs, These differences, maybe due to height, mixing of sample or the high difference in the temperature inside of chamber between designs. The N2O and CH4, fluxes were more higher in the conventional design (smaller) than in the proposal design because them are trace gases and big chambers could lose sensibility (limit of detection). The Conventional and Gas Pooling methodologies preserve the same tendency in the fluxes and differ between 1-6% in CH4, 10-20% in CO2, and 36% in N2O, the mostly case this percent it's due to outliers in the average.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Menjivar Flores, Juan Carlos and Chirinda, Ngonidzashe
Palabras clave:Cámara estática cerrada, Static-closed chamber, Designs, Methane, Nitrous oxide, Dioxide Carbon, Gas Pooling, Diseños, Metano, Óxido nitroso, Dióxido de carbono, Gas Pooling
Temática:6 Tecnología (ciencias aplicadas) / Technology
6 Tecnología (ciencias aplicadas) / Technology > 63 Agricultura y tecnologías relacionadas / Agriculture
Unidad administrativa:Sede Palmira > Facultad de Ingeniería y Administración > Maestría en Ingeniería Ambiental
Código ID:51898
Enviado por : Unnamed user with email lnarenasc@unal.edu.co
Enviado el día :16 May 2016 21:40
Ultima modificación:20 Junio 2016 16:43
Ultima modificación:20 Junio 2016 16:43
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox