Análisis y comparación dosimétrica de la irradiación corporal total por medio de las técnicas convencional 2D y Field-in-Field

Rodríguez Oyola, César Farid (2017) Análisis y comparación dosimétrica de la irradiación corporal total por medio de las técnicas convencional 2D y Field-in-Field. Maestría thesis, Universidad Nacional de Colombia - Sede Bogotá.

Texto completo

[img]
Vista previa
PDF - Versión Enviada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

8MB

Resumen

Una de las condiciones más importantes para el éxito en el trasplante de médula ósea es la inmunosupresión previa, esta puede lograrse por medio de quimioterapia y por radioterapia externa a través de la técnica denominada Irradiación Corporal Total o simplemente TBI. Tradicionalmente la TBI se realiza a distancias mayores a la de configuración del haz de radiación y por lo tanto no se utiliza el campo extendido sin un comisionamiento previo del mismo. De manera general la TBI se administra por medio de una técnica denominada 2D; en la cual la planeación del tratamiento se realiza por cálculos a punto sobre el eje central del paciente y verificando in vivo las dosis de entrada y salida a nivel del ombligo. En este trabajo se evalúa la posibilidad de usar el sistema de planificación dosimétrica ECLIPSE para los cálculos de dosis en TBI y en particular la herramienta Field In Field; para cumplir este objetivo se comisiona el haz de radiación de fotones de 18 MV de un acelerador SIEMENS PRIMUS perteneciente al Hospital Pablo Tobón Uribe, se verifica por medio del equipo de dosimetría, teniendo en cuenta las recomendaciones del protocolo TRS 398, que es posible su uso a distancias extendidas. Se encuentran variaciones en los parámetros dosimétricos PDD y TMR inferiores al 2 % de acuerdo con las referencias. También se realiza la planeación en diferentes TPS, encontrando similitud en los cálculos de las unidades monitor, siempre que las condiciones de planificación sean semejantes. Por medio del TPS ECLIPSE 15.6 se verifica la homogeneidad y conformación de la distribución de dosis encontrada. Valores aceptables en los índices de conformación y homogeneidad (IH=1,2, IC=0,9). Una vez evaluado el uso del TPS se genera la planeación del tratamiento en el software del equipo TomoHelical, donde se encuentran distribuciones de dosis con un buen cubrimiento y muy buena protección de los órganos a riesgo, reduciendo de esta forma la toxicidad inducida por la radiación en los mismos, Abstract: One of the most important conditions for success in bone marrow transplantation is the previous immunosuppression, this can be achieved through chemotherapy and external radiotherapy through the technique: Total Body Irradiation (TBI). Traditionally, the TBI is performed at greater distances than the configuration of the radiation beam and therefore the extended field is not used without prior commissioning and the planning of the treatment is performed by calculations on the central axis of the patient. In this work, the possibility of using the dosimetric planning system (TPS) for dose calculations in TBI is evaluated, for this purpose the radiation beam of 18 MV photons generated by a SIEMENS PRIMUS accelerator is commissioned, verifying by means of the dosimetry equipment, that its use at extended distances is possible. Variations in the dosimetric PDD and TMR parameters are found to be below 2 %. Planning is also carried out in different TPS, finding similarity in the calculations of the monitor units, provided that the planning conditions are similar. By means of the TPS ECLIPSE 15.6, the homogeneity and conformation of the dose distribution are verified, finding acceptable values in the conformation and homogeneity indexes (IH = 1.2, CI = 0.9). Once the use of TPS has been evaluated, treatment planning is generated in the TomoHelical equipment software, where better dose distributions and greater protection to organs at risk are found, reducing the radiation-induced toxicity in them.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Plazas de Pinzón, María Cristina and Mejía Montenegro, Alfonso
Información adicional:Magíster en Física Medica. Línea de Investigación Radioterapia.
Palabras clave:Dosis, Radiación, Gray, TBI, Isodosis, PTV, TPS, Dose, Radiation, TBI, Gray, Isodose
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
5 Ciencias naturales y matemáticas / Science > 57 Ciencias de la vida; Biología / Life sciences; biology
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
6 Tecnología (ciencias aplicadas) / Technology > 62 Ingeniería y operaciones afines / Engineering
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:64375
Enviado por : Cesar Farid Rodriguez Oyola
Enviado el día :18 Junio 2018 15:47
Ultima modificación:18 Junio 2018 15:47
Ultima modificación:18 Junio 2018 15:47
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox