Consistencia interna de la batería de evaluación propioceptiva en personas con amputación transtibial (BEPAT) en el Hospital Militar Central

Landínez-Parra, Nancy Stella and Núñez, Lady Marcela and Sierra, Ana Cecilia and Quiroga, Laura Catalina and Villamizar, Gladys Eugenia (2016) Consistencia interna de la batería de evaluación propioceptiva en personas con amputación transtibial (BEPAT) en el Hospital Militar Central. Revista de la Facultad de Medicina, 64 (3Sup). S9-S16. ISSN 2357-3848

Texto completo

[img]
Vista previa
PDF - Versión Publicada
Available under License Creative Commons Attribution Non-commercial.

1MB

URL oficial: https://revistas.unal.edu.co/index.php/revfacmed/a...

Resumen

Introducción. Varías pruebas clínicas han sido diseñadas para evaluar la propiocepción, sin embargo ninguna cuenta con la suficiente validez para ser empleada en población amputada. Por esta razón, el Grupo de Investigación de Profundización en Kinesioterapia de la Universidad Nacional de Colombia ha desarrollado una batería de evaluación propioceptiva para personas con amputación transtibial ya protetizadas (BEPAT). La presente investigación evalúa la consistencia interna de la batería. Objetivo. Establecer la consistencia interna de la batería de evaluación propioceptiva (BEPAT) en un grupo de amputados del Hospital Militar Central. Materiales y métodos. Estudio de tipo transversal en el que participaron 12 sujetos (25.4 ± 4.23 años) con amputación transtibial por mina, de género masculino (100%), y con tipo de prótesis de bloqueo-pin (75%). Los participantes asistieron al servicio de prótesis y amputados del Hospital Militar Central entre junio y julio de 2014, cumpliendo con los criterios de inclusión en el estudio. La consistencia interna se evaluó con el coeficiente alfa de Cronbach (α). Resultados. La BEPAT cuenta con una alta confiabilidad de tipo consistencia interna, con un valor global de coeficiente alfa α=0.758, mientras que este valor para los dominios de actividades efectoras, cinestesia y estatestesia fue de (α=-0.264), (α=0.829) y (α=0.763), respectivamente. Conclusiones. Se determinó que la BEPAT puede ser aplicable en el ámbito clínico, obteniendo en las primeras pruebas de confiabilidad un alto valor alfa de Cronbach α=0.758. Las variables que componen los dominios tienen una influencia positiva en la consistencia interna de toda la batería y las calificaciones para la pierna amputada se reducen, reportando valores inferiores a 26, lo que indica una regular respuesta propioceptiva., Introduction: Several clinical trials are designed to assess proprioception, however, none of them has sufficient validity to be used in amputee population. For this reason, the Kinesiotherapy Research Group from Universidad Nacional de Colombia has developed a proprioceptive test battery for below-knee amputation (BEPAT) with prosthetics. This research evaluates the internal consistency of the battery. Objective: To establish the internal consistency of a proprioceptive test battery (BEPAT) in a group of amputees treated at Hospital Militar Central. Materials and methods: Cross-sectional study which involved 12 male subjects (100%) (aged 25.4 ± 4.23) with transtibial amputation caused by landmine, and pin locking prosthesis (75%). Participants attended the prosthesis and amputees service at Hospital Militar Central between June and July 2014, meeting the criteria for inclusion in the study. Internal consistency was assessed with Cronbach’s alpha (α). Results: BEPAT has a high internal consistency reliability, with a total alpha coefficient value of α=0.758. This value, for the domains of effector activities, kinesthesia and statesthesia, was (α=-0.264), (α=0.829) and (α=0.763), respectively. Conclusions: It was determined that BEPAT may be applicable in a clinical setting, obtaining in a high Cronbach’s of α=0.758 during the first tests of reliability. The variables that comprise the domains have a positive influence on the internal consistency of the entire battery, and qualifications for the amputated leg are reduced, reporting values below 26, which indicates a regular proprioceptive response.

Tipo de documento:Artículo - Article
Palabras clave:Proprioception, Amputation, Evaluation, Propiocepción, Amputación, Evaluación
Temática:6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Revistas electrónicas UN > Revista de la Facultad de Medicina
Código ID:66194
Enviado por : Dirección Nacional de Bibliotecas STECNICO
Enviado el día :18 Septiembre 2018 21:19
Ultima modificación:18 Septiembre 2018 21:19
Ultima modificación:18 Septiembre 2018 21:19
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox