Desarrollo y validación de un método multiresiduo para el análisis de plaguicidas en miel por UFLC-MS

Zamudio S., Adriana M. and Vanoy V., Nicolás and Díaz Moreno, Consuelo and Ahumada Forigua, Diego Alejandro (2017) Desarrollo y validación de un método multiresiduo para el análisis de plaguicidas en miel por UFLC-MS. Revista Colombiana de Química, 46 (2). pp. 24-36. ISSN 2357-3791

Texto completo

[img]
Vista previa
PDF - Versión Publicada
Available under License Creative Commons Attribution.

1MB

URL oficial: https://revistas.unal.edu.co/index.php/rcolquim/ar...

Resumen

Se desarrolló un método para la determinación de residuos de plaguicidas en miel de abejas mediante cromatografía líquida ultra rápida acoplada a espectrometría de masas (cuádruplo sencillo). Se partió del método QuEChERS, evaluando las siguientes variables: (i) cantidad de muestra, (ii) tipo de sal para el control de pH, (iii) valor de pH del buffer y (iv) mezclas de limpieza. Adicionalmente y con el propósito de demostrar la confiabilidad del método, se evaluaron diferentes parámetros como exactitud, límites de detección y cuantificación, linealidad y selectividad. Los resultados mostraron que, mediante las modificaciones realizadas, se logró obtener un método más selectivo y se mejoró la exactitud de 19 plaguicidas respecto al método QuEChERS original. Por otro lado, mediante el proceso de validación, se encontró que el método es apto para el análisis de 50 plaguicidas (de 56 que se emplearon). Se obtuvieron porcentajes de recuperación entre el 70 y 120% y coeficientes de variación inferiores al 15%., A method for the determination of pesticide residues in honey by ultra fast liquid chromatography coupled with mass spectrometry was developed. For this purpose, different variations of the QuECHERS method were performed: (i) amount of sample, (ii) type of salt to control pH, (iii) buffer pH, and (iv) different mixtures for cleaning-up. In addition, to demonstrate that the method is reliable, different validation parameters were studied: accuracy, limits of detection and quantification, linearity and selectivity. The results showed that by means of the changes introduced it was possible to get a more selective method that improves the accuracy of about 19 pesticides selected from the original method. It was found that the method is suitable for the analysis of 50 pesticides, out of 56. Furthermore, with the developed method recoveries between 70 and 120% and relative standard deviation below 15% were found.

Tipo de documento:Artículo - Article
Palabras clave:Pesticides, QuEChERS, honey, validation, Plaguicidas, QuEChERS, Miel, Validación
Temática:5 Ciencias naturales y matemáticas / Science > 54 Química y ciencias afines / Chemistry
Unidad administrativa:Revistas electrónicas UN > Revista Colombiana de Química
Código ID:67292
Enviado por : Dirección Nacional de Bibliotecas STECNICO
Enviado el día :18 Septiembre 2018 21:19
Ultima modificación:18 Septiembre 2018 21:19
Ultima modificación:18 Septiembre 2018 21:19
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox