Determinación de los niveles de referencia para estudios de radiología convencional en el Hospital Universitario Nacional de Colombia

Torres Angarita, Luz Dary (2018) Determinación de los niveles de referencia para estudios de radiología convencional en el Hospital Universitario Nacional de Colombia. Maestría thesis, Universidad Nacional de Colombia - Sede Bogotá.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB

Resumen

Los niveles de referencia en radiología sirven como guía para aplicar medidas que permitan asegurar las exposiciones de pacientes a radiación ionizante y mediante éstos iniciar procesos de optimización, con el objetivo de obtener una calidad de imagen aceptable para el diagnóstico. Parte fundamental para la determinación de los también llamados niveles orientativos, fue realizar el control de calidad de los equipos convencionales de rayos X, esto con el fin de garantizar la confiabilidad de las medidas. Se usaron dos métodos para medir la dosis de entrada en superficie; el primero mediante la utilización del rendimiento del tubo con parámetros propios por cada estudio incluyendo un factor de retrodispersión y el segundo método mediante dosímetros termoluminiscentes. Los niveles de referencia fueron determinados en el Hospital Universitario Nacional para el estudio de tórax por ser el de más alta frecuencia, columna lumbar por ser uno de los estudios que más implica dosis de radiación y abdomen, para cada uno de estos estudios, se realizó la evaluación clínica de la imagen en al menos una de sus proyecciones. Los resultados arrojan niveles de referencia inferiores a los niveles internacionales, lo que puede atribuirse a los avances de la radiología digital, sin embargo, se recomienda dar inicio al proceso de optimización del servicio, implementando el factor de rechazo y realizando el entrenamiento en el funcionamiento del control automático de exposición, como herramienta fundamental de disminución de dosis de radiación, con el fin de llegar a la estandarización de los protocolos de adquisición para la mayoría de estudios de radiografía convencional., Abstract: Reference levels in radiology work as a guide to apply actions which ensure doses of patients exposed to ionizing radiation and begin through them processes of optimization, with the aim to obtain an acceptable diagnosis image quality. A fundamental issue for determining the so called indicative levels was the development of the quality control of the X-ray conventional equipment in order to guarantee the reliability of measurements. Two methods were used to measure the surface entrance dose, the former through the use of the tube efficiency with specific parameters for each exam including a backscatter factor, the latter by using thermoluminescent dosimeters. The reference levels were established at the Hospital Universitario Nacional for thorax exam as it is the most frequent, lumbar spine since it involves greater radiation doses and abdomen. The clinical evaluation of the image was made for every exam at least on one of its projections. Results produced reference levels below the international levels, which can be explained by the advances in digital radiology. However, it is suggested that the process of optimization of the installation is started by introducing the scrap factor and training in the operation of the automatic exposure control as an essential tool to diminish radiation doses withthe purpose of reaching the standardization of the acquisition protocols of the majority of conventional radiography exams.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Plazas de Pinzón, Maria Cristina
Información adicional:Magíster en Física Médica. Línea de Investigación:Radiología.
Palabras clave:Niveles de Referencia, Control de Calidad, Dosimetría, Radiología Convencional, Reference levels, Quality control, Dosimetry, Conventional radiology
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:70904
Enviado por : luz dary torres angarita
Enviado el día :07 Febrero 2019 17:14
Ultima modificación:07 Febrero 2019 17:14
Ultima modificación:07 Febrero 2019 17:14
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox