Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Autoeficacia percibida y adherencia al CPAP (presión positiva continua en la vía aérea) en personas con apnea del sueño

Gómez-Martínez, Astrid Yohana (2019) Autoeficacia percibida y adherencia al CPAP (presión positiva continua en la vía aérea) en personas con apnea del sueño. Maestría thesis, Universidad Nacional de Colombia-Sede Bogotá.

Texto completo

[img] PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB

Resumen

Objetivo: Determinar la relación entre la autoeficacia percibida y la adherencia objetiva al CPAP en una población de pacientes con SAHOS de una institución especializada en cuidado respiratorio de la ciudad de Bogotá. Método: Se utilizó un diseño de corte transversal con abordaje cuantitativo - correlacional, a partir de una corte de pacientes con Síndrome de Apnea Obstructiva del Sueño (SAHOS) moderado o severo. Entre los meses de septiembre y noviembre de 2018, se incluyeron de forma consecutiva 136 pacientes, hombres y mujeres, mayores de edad, que usaban CPAP y asistieron a consulta de neumología, sueño, rehabilitación y exámenes diagnósticos. Se obtuvo información demográfica y clínica. Cada participante diligenció el instrumento SEMSA para evaluar la autoeficacia y se obtuvo lectura de tarjeta del dispositivo, para evaluar adherencia objetiva. Se analizaron los datos por medio de un modelo de regresión logística. Resultados y conclusiones: La correlación entre la autoeficacia y la adherencia objetiva al CPAP, mostró un coeficiente de Sperman -,076. En el análisis discriminado, la dimensión autoeficacia de la escala de autoeficacia, mostró una correlación débil (Rho Sperman=0.17) estadísticamente significativa (p=0.048), lo cual concuerda con lo reportado en algunas publicaciones hechas en poblaciones diferentes a la estudiada. La puntuación de la dimensión de autoeficacia (3,4/4) fue superior a lo informado en la literatura, y la de expectativas de riesgo (1,85/4) fue inferior a lo reportado. Los pacientes jóvenes tuvieron una mayor autoeficacia que las personas mayores. La adherencia objetiva al CPAP (uso de CPAP > a 4 horas/noche por más del 70% de las noches) fue del 66,9 % con un promedio de horas de uso por noche de 5,54, valores más altos que los reportados a nivel mundial y local. Otras variables no tuvieron asociación con la adherencia., Abstract: Objective: To determine the relationship between perceived self-efficacy and objective adherence to CPAP in a population of patients with OSAHS from an institution specialized in respiratory care in the city of Bogotá. Method: This is a cross-sectional design with a quantitative-correlational approach, based on a cut-off of patients with moderate or severe obstructive sleep apnea OSAHS. Between the months of September and November of 2018, 136 patients were included; both gender male and female, which were above legal age 18 years old, users of CPAP machine and who attended to the pulmonology consultation, sleep, rehabilitation and diagnostic tests. Demographic and clinical information was obtained. Each participant completed the instrument in order to evaluate self-efficacy. Also, to evaluate objective adherence, card reading of the CPAP device, was obtained. The data was analyzed by logistic regression model. Results and conclusions: The correlation between self-efficacy and objective adherence to CPAP showed a Sperman coefficient of -,076. In the discriminated analysis, the self-efficacy dimension of the self-efficacy scale showed a weak correlation (Rho Spermean = 0.17) statistically significant (p = 0.048), in the sense that the information is relevant. The score of the dimension of self-efficacy (3.4 / 4) was higher and reported in the literature, but lower in the domain of risk expectations (1.85 / 4). Young patients had greater self-efficacy than older patients. Objective adherence to CPAP (use of CPAP> at 4 hours / night for more than 70% of the nights) was 66.9% with an average nighttime usage of 5.54, higher values than those reported Globally and locally. Other variables had no association with adherence.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Flórez Flórez, Magda Lucía
Información adicional:Magíster en Enfermería.
Palabras clave:Síndrome de apnea del sueño, Autoeficacia, Adherencia, CPAP, Teoría de autoeficacia, Sleep apnea syndrome, Self-efficacy, Adherence, CPAP, Theory of self-efficacy
Temática:6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Enfermería > Centro de Extension y de Investigación en Enfermería
Sede Bogotá > Facultad de Enfermería > Departamento del Cuidado y Práctica de la Enfermería > Enfermería
Código ID:72336
Enviado por : Enfermera Astrid Yohana Gómez Martínez
Enviado el día :20 May 2019 16:54
Ultima modificación:20 May 2019 16:54
Ultima modificación:20 May 2019 16:54
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Metabiblioteca OAIster BASE BDCOL Registry of Open Access Repositories SNAAC Red de repositorios latinoamericanos eprints Open archives La referencia Tesis latinoamericanas OpenDOAR CLACSO
Este sitio web se ve mejor en Firefox