Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Desarrollo de un modelo de cálculo de dosis en tratamientos de cáncer de próstata con IMRT utilizando la herramienta GEANT4 de simulación Monte Carlo

Ayala Álvarez, David Santiago (2012) Desarrollo de un modelo de cálculo de dosis en tratamientos de cáncer de próstata con IMRT utilizando la herramienta GEANT4 de simulación Monte Carlo. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

6MB

Resumen

En este trabajo se presenta la implementación de un modelo de cálculo de dosis con base en la herramienta Geant4 de simulación Monte Carlo. Se realizaron pruebas de validación del método utilizando un simulador físico homogéneo de agua irradiado con haces de fotones de 6MeV generados en un acelerador lineal de electrones de uso clínico. El código final utiliza como entrada un conjunto de imágenes dicom de un paciente real generadas a partir de una voxelización de imágenes de CT adquiridas en el Instituto Nacional de Cancerología y espacios de fases generados en el cabezal del acelerador, en los cuales se ha almacenado información de partículas antes y después de colimadores secundarios y multilaminar. Se evaluaron configuraciones para radioterapia convencional, conformal (3DCRT) y una aplicación particular con la técnica de radioterapia de intensidad modulada, IMRT. Los resultados de la simulación fueron comparados con los resultados de la planeación realizada en un sistema de cálculo de dosis comercial. Los cálculos en el simulador físico homogéneo de agua fueron comparados con mediciones hechas con una cámara de ionización en una configuración similar. Para este caso, los resultados concordaron con errores inferiores al 4% para las curvas de PDD, aunque los perfiles en las distribuciones de dosis mostraron una posible fuga en el colimador multilláminas simulado. Para el simulador físico antropomórfico, los resultados de la simulación presentan grandes diferencias en cuanto a la distribución de dosis obtenida, según lo indican los histogramas dosis - volumen obtenidos para diferentes estructuras irradiadas durante el tratamiento con radioterapia. / Abstract: This paper presents the implementation of a Geant4 based simulation tool for dose calculations with Monte Carlo. Tests were conducted to validate the method using a homogeneous water phantom irradiated with 6MeV photon beams generated by an electron linear accelerator for clinical use. The final code uses as data input a set of dicom images of a real patient generated from a CT imaging voxelization acquired in the National Cancer Institute and phase spaces generated in the accelerator head, in which particles information before and after secondary multileaf collimators has been stored. Configurations were evaluated for conventional radiotherapy, conformal (3DCRT) and a particular application for intensity modulated radiotherapy, IMRT. The simulation results were compared with the plan carried out in a commercial planning system. Calculations in the water phantom were compared with measurements made with an ionization chamber in a similar configuration. For this case, the results were consistent with errors below 4% for PDD curves, although the profiles in the dose distributions showed a possible leak in the simulated multileaf collimator. For the antropomorphic phantom simulation results show great diferences in the dose distribution obtained, as indicated by the histograms dose - volume for various structures irradiated during radiotherapy.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Muñoz, Jose Daniel and Mejía Montenegro, Alfonso
Información adicional:Magister en Física Médica.
Palabras clave:Cáncer de próstata; Radioterapia; IMRT; Monte Carlo; Geant4 / Prostate cáncer; Radiotherapy; IMRT; Monte Carlo; Geant4
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:8982
Enviado por : Universidad Nacional de Colombia Biblioteca Digital -3- Sede Bogotá
Enviado el día :11 Enero 2013 15:36
Ultima modificación:11 Enero 2013 15:36
Ultima modificación:11 Enero 2013 15:36
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox